Type: | Switch Cabinet |
---|---|
Max. Current: | 630A |
Max. Voltage: | 12kv |
Withstand Current: | 20ka,16ka |
Rated Voltage: | 12kv |
Load Breaking Current: | 630A |
Suppliers with verified business licenses
GSC-SC6 12kv Sf6 Load Break Switch in High Voltage Rmu
Introducing the SF6 load break switches by GRENO (XIAMEN) SWITCHGEAR CO., LTD., designed to meet the switching needs of circuits with currents up to 630 A in 6 kV, 10 kV, and 20 kV/24kV/50 Hz three-phase A.C. networks. These switches are the perfect solution for efficient and reliable circuit switching. GRENO (XIAMEN) SWITCHGEAR CO., LTD. offers high-quality SF6 load break switches that are specifically designed for switching circuits with currents up to 630 A in 6 kV, 10 kV, and 20 kV / 24kV / 50 Hz three-phase A.C. networks.
We strictly control product quality and choose the best quality epoxy resin, even if it may be expensive. Before each production, we will make a strip sample with epoxy resin to ensure its quality. Based on the test data, we have successfully controlled the quality of the main materials, such as bending strength, tensile strength, and impact strength.
Our internal contact terminals are made of permanent magnet materials, ensuring reliable performance. When LBS switches to the disconnected position, the arc naturally becomes thinner and causes self extinguishing in SF6 gas.
We warmly welcome any inquiries at any time. Please feel free to send us your questions or requests, and we will be happy to assist you.
Introducing our latest switchgear with enhanced features and benefits:
The insulation ability for arc-extinguishing is significantly improved when the switchgear is in an open status. This is achieved by filling the switchgear with SF6 gas at a pressure range of 0.03Mpa~0.04Mpa.
We have designed our switchgear to be smaller in size without compromising on safety. By utilizing advanced techniques, we have successfully made the whole size of the switchgear smaller, making it easier to install and handle.
Our switchgear features a copper contactor with over 99.95% Cu content. This special production process ensures the contactor's excellent abrasion rigidity. We proudly call this material T2 copper.
In order to enhance safety, we have designed our switchgear with a phased distance of 210mm. This particular design extends the air and creepage distance, minimizing the risk of electrical accidents.
Item NO. | Name | Unit | Technical parameters | |||
Load break switch panel | ||||||
1 | Rated Voltage Un | kV | 12 | 24 | 36 | |
2 | Rated Frequency | Hz | 50 | 50 | 50 | |
3 | Rated Current | A | 630 | 630 | 630 | |
4 | Rated Load Breaking Current | A | 630 | 630 | 630 | |
5 | Rated Short Time Withstand Current(rms) | kA | 20 | 20 | 20 | |
6 | Rated Short Time Duration | s | 3 | 3 | 3 | |
7 | Rated Peak Withstand Current | kA | 50 | 50 | 50 | |
8 | Rated Closed Switch - Off Current | A | 630 | 630 | 630 | |
9 | Rated Cable Charging Breaking Current | A | 10 | 10 | 10 | |
10 | Rated Active Load Breaking Current | A | 630 | 630 | 630 | |
13 | Earthing Switch 2s Short Time Withstand Current | kA | 20 | 20 | 20 | |
14 | Rated Short-Circuit Current Making Times | times | 2 | 2 | 2 | |
15 | Rated Current Breaking Times | times | 10 | 10 | 10 | |
16 | Mechanical Endurance | Load Break Switch | times | 3000 | 3000 | 3000 |
Earthing Switch | times | 2000 | 2000 | 2000 | ||
17 | SF6 gas anual leakage rate≤ | /year | 0.10% | 0.10% | 0.10% | |
18 | Rated Insulation Level | Unit | Technical parameters | |||
1min Power Frequency withstand voltage(rms) | On isolating distance | kV | 48 | 60 | 110 | |
Phase to Phase | kV | 42 | 50 | 85 | ||
Phase to Earth | kV | 42 | 50 | 85 | ||
Lightning impulse withstand voltage(peak) | On isolating distance | kV | 85 | 145 | 215 | |
Phase to Phase | kV | 75 | 125 | 185 | ||
Phase to Earth | kV | 75 | 125 | 185 |