• 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
  • 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
  • 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
  • 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
  • 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
  • 24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch

24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch

Breaking Capacity: Overhead Line
Operation: Manual or Motorized
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Overhead Line
Structure: Lbs
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GPS-BP-12/24
Poles Number
3
Type
Overhead Line Lbs
Certification
ISO9001-2000
Transport Package
Wooden Case
Trademark
GRENO
Origin
Xiamen, China
Production Capacity
50000PCS/Year

Product Description

Outdoor 12KV 24KV 33KV 35KV 36KV 40.5KV High Voltage SF6 Sulfur Hexafluoride Gas Air Load Break Switch LBS 630A 1250A

Product Description

GPS type outdoor pole-mounted HV AC SF6 insulation load break switch is suitable to the distribution network with rated voltage 12-40.5kV, rated current 630A, three-phase AC 50/60Hz to open and close the load current and short circuit current in the power system. It can automatically disconnect the distribution line segment in which the fault occurred. Equipped with the advanced electronic controller, the switch can be for manual operation, electric operation and remote operation. The electronic controller is installed in a stainless steel cabinet, so it can be used in all kinds of climatic conditions. The wire and wireless modems can be also installed in the cabinet to realize remote monitoring and control. Simple, convenient and quick pole mounting can lower the installation cost. The product conforms to the standards of IEC60265-1, IEC62271-103 & GB/T3804: 3.6kV~40.5kV AC high voltage load break switch and IEC60694 & GB/T11022: high voltage switch apparatus and control device.

Ambient conditions

1. Altitude: ≤3000m;
2. Ambient temperature: -40ºC~+50ºC;diurnal temperature rang ≤25ºC;
3. Wind speed: ≤35m/s, equivalent to wind pressure of 700Pa;
4. Earthquake intensity: ≤grade 8;
5. Relative humidity: 100%;
6. Ice thickness: ≤10mm
7. Pollution degree: ≤4(GB5582);
8. Applicable occasions: no fire and explosion danger, no chemical corrosion and no frequent severe vibration.

Features
1. Stainless steel enclosure has good antisepsis and seal performance.
2. Light in weight and convenient for transportation.
3. Maintenance free and low leakage rate.
4. With explosion-proof device.
5. Bushing could be porcelain/ polymeric
6. Quick close & open
7. Amazing load breaking and fault making capacity.


Technical Satisfaction

Products Type GPS-12 GPS-24 GPS-38
Basic Ratings
Rated Voltage  15 kV 25.8 kV 38 kV
Rated Continuous Current  630 A 630 A 630 A
Rated Frequency  50/60 Hz 50/60 Hz 50/60 Hz
Short Time Withstand Current ( rms) 20 kA/ 4sec 25kA/ 1sec 20 kA/1 sec
Making and Breaking Capacity
Mainly Active Load Current  630A 630A 630A
Number of Load-break Operation  400 times 400 times 400 times
Short-circuit Making Current (peak)  50 kAp/4s 31.5kAp/4s 31.5 kAp/4s
Number of Making Operations  5 times 5 times 5 times
Cable Charging Current  25A 25A (200 A) 20 A
Line Charging Current  1.5A 1.5A 2A
Closed Loop Circuit Current  630 A 630 A 630 A
Transformer Magnetizing Current 22A 22A 22A
Power Frequency Withstand Current Test 
Wet Condition- 10 sec  (Ph- Ph, Ph-Eth, Across Interrupters) 45 kV 50kV 70 kV
Dry Condition - 1 min(Phase to Earth, Phase to Earth) 50 kV 60kV 70 kV
Dry Condition - 1 min  (Across Interrupter ) 50 kV 60kV 80 kV
Impulse Withstand Current Test ( 1.2 x 50 ps )
Phase to Phase, Phase to Earth  85 kV 150kV 170 kV
Across Interrupter 95 kV 150kV 195 kV
Other Ratings & Specifications 
InternaArc Tes 20kA /0.1 sec 20kA /0.1 sec 20kA /0.1 sec
Arc Extinction Medium  SF 6 Gas SF 6 Gas SF 6 Gas
Insulation Medium  SF 6 Gas SF 6 Gas SF 6 Gas
Creepage Distance (Porcelain) 550 mm 740 mm 960 mm
Creepage Distance (Silicon) 615 mm 800 mm 1055 mm
IP Leve 54 54 54
Operation Performance 
Closing/Opening Time  < 0.7 sec < 0.7 sec < 0.7 sec
Mechanical Operations (Guaranteed) 10,000 10,000 10,000
  times times times
Operating Temperature (*Manual -25 (*-40) -25 (-40) -25 (-40)
Type) ~ 70° C ~ 70° C 70° C
Gas Pressure
Nominal Pressure (kgf/cm2 G, at 20°C))  0.7 1.0 1.0
Bursting Pressure (kgf/cm2 G) 4 ~6 4 ~6 4 ~6
Minimum Gas Pressure (kgf/cm2 G) 0.05 0.0 0.0
Leakage Rate (cc/ sec)  1.1 x 10 -7 1.1 x 10 -7 8.2 x 10-7
24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch
24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch



24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch24kv Outdoor Pole Mount Type Sf6 Gas Insulated Load Break Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11