• 36kv Switch, Load Break Switch, 40.5kv Breaker
  • 36kv Switch, Load Break Switch, 40.5kv Breaker
  • 36kv Switch, Load Break Switch, 40.5kv Breaker
  • 36kv Switch, Load Break Switch, 40.5kv Breaker
  • 36kv Switch, Load Break Switch, 40.5kv Breaker
  • 36kv Switch, Load Break Switch, 40.5kv Breaker

36kv Switch, Load Break Switch, 40.5kv Breaker

Type: High-voltage
Structure: Double-column Disconnector
Installation: Outdoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC
Number of Poles
Three Pole
Grounding
Double Ground
Series
Three
Run
Swing
Switching Mode
Double-Throw Type
Common Model
DR
Structure of Operating
Electric
Certification
IS9001, ISO9001, ISO9002, ISO2000
Brand
Greno
Transport Package
Wooden Case
Specification
Phase distance: 350mm
Trademark
GRENO
Origin
Xiamen
Production Capacity
5000sets/Year

Product Description

Warmly wecome to Send us any enquiries anytime"
36kv Switch, Load Break Switch, 40.5kv Breaker



We focus on every detail 
36kv Switch, Load Break Switch, 40.5kv Breaker

GSC-36,
Completely under IEC international standard and GB standard.
Arc-extinguishing and insulation by SF6 gas.
Especially suitable for secondary distribution.
36kv Switch, Load Break Switch, 40.5kv Breaker



++++ Main technical specifications
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 183 184 185
Note: For short circuit breaking and peak current is based on Fuse plus combination.
Our Services
12 months warranty
Type test, technical and marketing support.   
Warmly welcome customized design.
After-sales service ..
 36kv Switch, Load Break Switch, 40.5kv Breaker36kv Switch, Load Break Switch, 40.5kv Breaker36kv Switch, Load Break Switch, 40.5kv Breaker
1.What is the payment term?
 T/T, wire transfer, west union
2. What kind of VCB do you have?
We have 12kv,24kv,36kv,40.5kv lateral type and withdrawable type vacuum circuit breaker.
3. Warranty period?
Normally 12 months.
 3.How about type test?
Our client passed type test in Europe, and we also type tested in China.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11