Feature: | Electrical or Manual Control |
---|---|
Application: | Industrial |
Type: | Circuit Breaker |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The GPS type pole-install load switch is designed for use in power systems with a rated voltage of 12kV, 24kV, or 33kV. It has a rated current of 400/630A and operates at a frequency of 50/60HZ. This switch is used to control the load current, over load current of power line open circuit, and opening and closing of electric systems.
The switch is equipped with a state-of-the-art controller that offers advanced technical parameters.
Products Type | GPS-12 | GPS-24 | GPS-38 |
Basic Ratings | |||
Rated Voltage | 15 kV | 25.8 kV | 38 kV |
Rated Continuous Current | 630 A | 630 A | 630 A |
Rated Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Short Time Withstand Current ( rms) | 20 kA/ 4sec | 25kA/ 1sec | 20 kA/1 sec |
Making and Breaking Capacity | |||
Mainly Active Load Current | 630A | 630A | 630A |
Number of Load-break Operation | 400 times | 400 times | 400 times |
Short-circuit Making Current (peak) | 50 kAp/4s | 31.5kAp/4s | 31.5 kAp/4s |
Number of Making Operations | 5 times | 5 times | 5 times |
Cable Charging Current | 25A | 25A (200 A) | 20 A |
Line Charging Current | 1.5A | 1.5A | 2A |
Closed Loop Circuit Current | 630 A | 630 A | 630 A |
Transformer Magnetizing Current | 22A | 22A | 22A |
Power Frequency Withstand Current Test | |||
Wet Condition- 10 sec (Ph- Ph, Ph-Eth, Across Interrupters) | 45 kV | 50kV | 70 kV |
Dry Condition - 1 min(Phase to Earth, Phase to Earth) | 50 kV | 60kV | 70 kV |
Dry Condition - 1 min (Across Interrupter ) | 50 kV | 60kV | 80 kV |
Impulse Withstand Current Test ( 1.2 x 50 ps ) | |||
Phase to Phase, Phase to Earth | 85 kV | 150kV | 170 kV |
Across Interrupter | 95 kV | 150kV | 195 kV |
Other Ratings & Specifications | |||
InternaArc Tes | 20kA /0.1 sec | 20kA /0.1 sec | 20kA /0.1 sec |
Arc Extinction Medium | SF 6 Gas | SF 6 Gas | SF 6 Gas |
Insulation Medium | SF 6 Gas | SF 6 Gas | SF 6 Gas |
Creepage Distance (Porcelain) | 550 mm | 740 mm | 960 mm |
Creepage Distance (Silicon) | 615 mm | 800 mm | 1055 mm |
IP Leve | 54 | 54 | 54 |
Operation Performance | |||
Closing/Opening Time | < 0.7 sec | < 0.7 sec | < 0.7 sec |
Mechanical Operations (Guaranteed) | 10,000 | 10,000 | 10,000 |
times | times | times | |
Operating Temperature (*Manual | -25 (*-40) | -25 (-40) | -25 (-40) |
Type) | ~ 70° C | ~ 70° C | 70° C |
Gas Pressure | |||
Nominal Pressure (kgf/cm2 G, at 20°C)) | 0.7 | 1.0 | 1.0 |
Bursting Pressure (kgf/cm2 G) | 4 ~6 | 4 ~6 | 4 ~6 |
Minimum Gas Pressure (kgf/cm2 G) | 0.05 | 0.0 | 0.0 |
Leakage Rate (cc/ sec) | 1.1 x 10 -7 | 1.1 x 10 -7 | 8.2 x 10-7 |