• High Voltage 12kv Sf6 Gas Load Break Switch
  • High Voltage 12kv Sf6 Gas Load Break Switch
  • High Voltage 12kv Sf6 Gas Load Break Switch
  • High Voltage 12kv Sf6 Gas Load Break Switch
  • High Voltage 12kv Sf6 Gas Load Break Switch
  • High Voltage 12kv Sf6 Gas Load Break Switch

High Voltage 12kv Sf6 Gas Load Break Switch

Type: Switch Cabinet
Max. Current: 630A
Max. Voltage: 12kv
Withstand Current: 20ka,16ka
Rated Voltage: 12kv
Load Breaking Current: 630A
Samples:
US$ 600/set 1 set(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC-SC6
Altitude
2500m
Standard
IEC,ANSI,Ceb,GB
Transport Package
Carton, Wooden Case
Specification
Phase distance: 210mm
Trademark
GRENO
Origin
Xiamen
Production Capacity
1500sets/Month

Product Description

SF6 Load Break Switches

Designed by GRENO (XIAMEN) SWITCHGEAR CO., LTD., SF6 load break switches are perfect for switching circuits with currents up to 630 A in 6 kV, 10 kV, and 20 kV/24kV/50 Hz three-phase A.C. networks.

Features:


  • High-quality SF6 load break switches

  • Designed for currents up to 630 A

  • Compatible with 6 kV, 10 kV, and 20 kV/24kV/50 Hz three-phase A.C. networks

Benefits:


  • Efficient switching of circuits

  • Reliable performance

  • Safe and durable

  • Perfect for various voltage levels
High Voltage 12kv Sf6 Gas Load Break SwitchHigh Voltage 12kv Sf6 Gas Load Break SwitchHigh Voltage 12kv Sf6 Gas Load Break Switch
 
High Voltage 12kv Sf6 Gas Load Break Switch

Introducing our latest innovation from GRENO (XIAMEN) SWITCHGEAR CO., LTD., the SF6 Gas Insulated Switchgear. This switchgear is providing enhanced insulation ability for arc-extinguishing when in open status. The switchgear is filled with SF6 gas at a pressure range of 0.03Mpa~0.04Mpa, ensuring optimal performance.

One of the key advantages of our SF6 Gas Insulated Switchgear is its compact size. We have safely made the whole size smaller, allowing for easy installation and space-saving benefits.

The copper contactor used in our switchgear is made from the best material available. With more than 99.95% Cu content and a special production process, the copper contactor guarantees exceptional abrasion rigidity. We refer to this material as T2 copper.

In addition, our SF6 Gas Insulated Switchgear features an increased phased distance of 210mm. This particular design elongates the air and creepage distance, ensuring enhanced safety and performance.

High Voltage 12kv Sf6 Gas Load Break Switch

We strictly control the quality of our products by using the best quality epoxy resin, despite its higher cost. Before every production, we conduct a belt transect test with epoxy resin to ensure its reliability. Based on the test data, we have effectively controlled the quality of major materials, including bending strength, tensile strength, and impact strength.

Our internal contact terminals are made of permanent magnetism material, ensuring their durability and longevity. When the LBS switches to the open position, the arc naturally becomes thinner and eventually extinguishes in SF6 gas. This feature enhances the safety and efficiency of our product.

We warmly welcome any inquiries at any time. Feel free to reach out to us with your questions or requests.

High Voltage 12kv Sf6 Gas Load Break Switch


We focus on every detail 
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125 185

GRENO (XIAMEN) SWITCHGEAR CO., LTD.
Our Services


  • 12 months warranty or longer (Negotiable)

  • Type test, technical, and marketing support

  • Warmly welcome customized design

  • After-sales service
High Voltage 12kv Sf6 Gas Load Break Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11