Product Description:
The three-phase AC 50Hz VSG series indoor high-voltage vacuum circuit breaker buried pole is suitable for 24kV indoor distribution equipment.
Its structure can effectively prevent the vacuum arc extinguishing chamber from being affected by external factors such as impact and dirt, making the circuit more capable of withstanding the rated short-term peak withstand current.
Electric poles are embedded or can be assembled according to your needs.
Indoor AC vacuum circuit breakers comply with:
-IEC56 and similar standards of other major industrialized countries
-IEC62271-100 High voltage switchgear and control equipment Part 1: AC circuit breakers
Features:
1. Pre embedded rods can greatly improve the reliability of insulation, mechanical and breaking performance, truly achieving free maintenance and longer electromechanical lifespan. Compared with traditional prefabricated poles, embedded poles save more fasteners and accessories such as wire joints.
2. The mechanism has both manual and electric options.
3. This product is suitable for various withdrawable metal armored switchgear and can be fixed for installation.
NO. |
Name |
Unit |
VSG |
1 |
Rated Voltage Un |
kV |
12 |
2 |
Rated Frequency |
Hz |
50 |
3 |
Rated Current |
A |
630 |
4 |
Rated Short-circuit Breaking Current |
kA |
31.5 |
5 |
Rated Short-circuit Making Current (Peak Value) |
kA |
80 |
6 |
Rated Short Time withstand Current(rms) |
kA |
31.5 |
7 |
Rated shor-circuit endurance |
s |
4 |
8 |
Rated peak withstand current |
kA |
80 |
9 |
Rated Cable Charging Breaking Current |
A |
25 |
10 |
Electrical Endurance Class |
Class |
E2 |
11 |
Capacitive Current Breaking and Making Capacity |
Cass |
C2 |
12 |
Mechanical Endurance |
Times |
10000 |
13 |
SF6 gas anual leakage rate |
|
|
|
14 |
Rated insulation level |
Unit |
|
1min power frequency withstand voltage (rms) |
On isolating distance |
kV |
48 |
Phase to phase |
kV |
42 |
Phase to earth |
kV |
42 |
Lightning Impulse Withstand Voltage(peak) |
On isolating distance |
kV |
85 |
Phase to phase |
kV |
75 |
Phase to earth |
kV |
75 |
1.We offer:
1). 12kv~24KV indoor sf6 load break switch with phase distance of 200mm,210mm,275mm .
2). 36kv type indoor sf6 load break switch
3).Upper compartment of oad break switch
4). Compartment of load break switch +fuse
2. Shipping
Always ready to help arrange sea/ air/ eaxpress shipping.
Each product is strictly tested before shipment.
1. What rates of indoor sf6 load break switch can you provide?
We offer 12kv,24kv,36kv sf6 load break switch ,for more informations ,welcome to contact us
FAQ:
2.What is the payment term?
T/T, wire transfer, west union
3. Warranty period?
Normally 12 months.
3.How about type test?
Our client passed type test in Europe, and we also type tested in China.