Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual or Motorized
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: Lbs
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
36kv High Voltage Sf6 Gas Load Break Switch
Poles Number
3
Type
Load Break Switch
Function
Load Break Switch
Certification
ISO9001-2000, Type Test Report
Transport Package
Wooden Case
Origin
Xiamen
Production Capacity
5000pieces Per Month

Product Description

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Product description

GSC-36 high/medium voltage SF6 load break switch, with a rated voltage of 12kv, 24kv or 36kv, can response and protect power system when there is an error. The switch can be either manual operation or electrical operation, and earthing function is optional. Switch fuse combination can protect the whole system.
Compact size, easy installation and free of maintainence make the switch suitable for wide applications, especially for ring main unit.  It also can work with vacuum circuit breaker to make a switchgear combination for excellent performance with favorable cost.
Indoor 36kv High Voltage Sf6 Gas Load Break Switch
1.normal operating conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
f) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

Indoor 36kv High Voltage Sf6 Gas Load Break SwitchIndoor 36kv High Voltage Sf6 Gas Load Break SwitchIndoor 36kv High Voltage Sf6 Gas Load Break SwitchIndoor 36kv High Voltage Sf6 Gas Load Break SwitchIndoor 36kv High Voltage Sf6 Gas Load Break Switch

We focus on every detail 

Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11