• Switch Sf6 Lbs for Switchgear
  • Switch Sf6 Lbs for Switchgear
  • Switch Sf6 Lbs for Switchgear
  • Switch Sf6 Lbs for Switchgear
  • Switch Sf6 Lbs for Switchgear
  • Switch Sf6 Lbs for Switchgear

Switch Sf6 Lbs for Switchgear

Certification: ISO9001, Type Test Report
Protection: Corrosion Resistance
Installation: Vertical
Housing: Stainless Steel
Transport Package: Carton
Specification: Phase distance: 210mm, 275mm
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC-SC6
Trademark
GRENO
Origin
Xiamen, China
Production Capacity
5000PCS/Year

Product Description

Switch Sf6 Lbs For Switchgear
GSC indoor AC High-voltage SF6 Load Break Switch,Load Break Switch-fuse combination unit and cable head installable Load Break Switch are deveoped with our own design, based on our digestion and absorption of foreign advanced technology, combined with China's operation requirement.This product past type test, the performance compply with IEC60265 and IEC60420 Standard.

Technical Satisfaction
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125 185
Switch Sf6 Lbs for SwitchgearSwitch Sf6 Lbs for SwitchgearSwitch Sf6 Lbs for SwitchgearSwitch Sf6 Lbs for SwitchgearSwitch Sf6 Lbs for Switchgear

This product has "joint-division-ground" three position arc chamber,with reliable interlocking, high reliable interlocking,high dielectric strength of fracture, design of large creepage path, and its leading-out terminal is protected by a voltage-sharing protection cover.For the cable head installable Load Break Switch, its outgoing end is equipped with touch-type cable connector,the outgoing line is installed with high-voltage cable, equipped with a voltmeter in a clear position for monitoring in operation to ensure safe operation,which is a new gener
ation of high voltage switchgear for urban power grid.Switch Sf6 Lbs for Switchgear

Switch Sf6 Lbs for Switchgear

Shipping

Each product is tested and packed in carton and wooden box(upon request) before delivery.

We can help arrange sea/air/express shipping. 

Switch Sf6 Lbs for Switchgear
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11