Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs

Type: High-voltage
Structure: Double-column Disconnector
Installation: Indoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC-SC6
Number of Poles
Three Pole
Grounding
Double Ground
Series
Three
Run
Vertical Rotation
Switching Mode
Double-Throw Type
Common Model
PR
Structure of Operating
Electric
Certification
ISO, IS9001, ISO9001, ISO9002, ISO2000
Brand
Greno
Transport Package
Carton
Specification
phase distance 210mm, 230mm, 275mm
Trademark
GRENO
Origin
Xiamen
Production Capacity
5000sets/Year

Product Description

Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs 

Product Description
GSC-36 is an indoor high-voltage SF6 load switch with a rated voltage of 36kV/40.5kV. It uses SF6 gas as the arc extinguishing and insulation medium, including three contactors for switch and grounding. It has the characteristics of small volume, easy installation and operation, and strong adaptability to the environment. Indoor high-voltage SF6 load switch GSC-36 and SF6 load switch with fuse combination GSC-36 can protect and control the electrical equipment of power supply substations and substations, especially suitable for ring main cabinets, cable branch cabinets, and distribution switch stations.
Compact size, easy installation and free of maintainence make the switch suitable for wide applications, especially for ring main unit.  It also can work with vacuum circuit breaker to make a switchgear combination for excellent performance with favorable cost.
 

Normal Operating Conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
f) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

Technical Satisfaction
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125
Note: For short circuit breaking and peak current is based on Fuse plus combination.
Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch LbsSupplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs
Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs


We focus on every detail 
Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs

Supplier Electric High Voltage 36kv Sf6 Gas Load Break Switch LbsSupplier Electric High Voltage 36kv Sf6 Gas Load Break Switch Lbs

Our Services
12 months warranty
Type test, technical and marketing support.   
Warmly welcome customized design.
After-sales service ..

 
    

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11