Type: Load Break Switch
Max. Current: 630A
Max. Voltage: 12kv
Withstand Current: 20ka,16ka
Rated Voltage: 12kv
Rated Current: 630A
Samples:
US$ 600/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC-SC6
Making Current
50ka
Standards
IEC,GB
Service Temperature
-35~40ºC
Humidity
95%
Operating
Motor
Transport Package
Carton Packing
Specification
140cm*87cm*123cm
Trademark
GRENO
Origin
Xiamen
Production Capacity
1500 Set/Sets Per Month

Product Description


characteristics :
Strictly implement standards such as IEC60256-1, IEC60420, GB3804-19901997, GB16926, etc....
Small size, easy to install and operate
Strong adaptability to the surrounding environment, suitable for high-altitude areas.


"Warmly wecome to Send us any enquiries anytime"
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000

Protect and control electrical equipment for power supply and substations.
Especially suitable for ring main cabinets, distribution switch stations, and cable distribution cabinets.
The natural interlocking system is simple and reliable, preventing misoperation and ensuring personal safety.
Even if the cable compartment door is open, the interlocking still works.

The pressure reducing valve is located at the rear of the air storage tank. When SF6 gas is overpressure due to arc faults, it can release internal pressure.
We supply:
1).The whole switchgear
2) SF6 load break switch top unit
2).12kv,24kv indoor sf6 load break switch (phase distance:210mm, 275mm )
3).36kv indoor sf6 load break switch 
5). Load break switch + fuse combination lower unit
3.  Operation mechanism 
Using a spring operated mechanism:
There are two types of mechanisms available for you to choose from: single spring and double spring.
Both types can be electrified by installing motor components.

12kv Sf6 Incoming Load Break Switch with Electric Mechanism12kv Sf6 Incoming Load Break Switch with Electric Mechanism12kv Sf6 Incoming Load Break Switch with Electric Mechanism
Packaging & Shipping
 A. Packaging 
Our standard package way is carton or wooden package according to customers' requirements.
B. Shipping
Each product is strictly tested before packing for delivery..
We're always ready to help arrange air/express/sea/ shipping.
12kv Sf6 Incoming Load Break Switch with Electric Mechanism12kv Sf6 Incoming Load Break Switch with Electric Mechanism

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11