36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6

Product Details
Type: Load Break Switch
Model Number: Gsc-Sc6
Max. Current: 630A
Still deciding? Get samples of US$ 800/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
ODM Services
The supplier provides ODM services
Quality Assurance
The supplier provides quality assurance
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (22)
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
  • 36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
Find Similar Products

Basic Info.

Model NO.
GSC
Max. Voltage
36kv
Withstand Current
20ka,16ka
Rated Voltage
36kv
Rated Current
630A
Rated Frequency
50/60Hz
Standard
IEC,ANSI,Ceb,GB
Certificate
ISO9001 So14001 OHSAS18001 CCC SGS
Transport Package
Wooden, Carton
Trademark
GRENO
Origin
Xiamen, China
Production Capacity
1500 Set/Sets Per Month

Product Description

36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
 

"Warmly wecome to Send us any enquiries anytime"
Product Description
GSC-36 high voltage SF6 load circuit breaker, with a rated voltage of 36kV, can respond and protect the power system in case of errors. The switch can be manually operated or electrically operated, with optional grounding function. The combination of switch and fuse can protect the entire system. The rated current of the fuse can be determined according to customer requirements. This switch is compact in size, easy to install, maintenance free, and suitable for a wide range of applications, especially circular hosts. It can also be used in conjunction with vacuum circuit breakers to achieve excellent performance and favorable cost.


 Main technical specifications
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
Note: For short circuit breaking and peak current is based on Fuse plus combination.

Features
The load switch adopts double break rotating moving contacts and has the following three states: Closing;Opening; Grounding.
Good insulation performance. The load switch uses SF6 as the arc extinguishing and insulation medium. The switch is sealed by upper and lower shells cast with epoxy resin.
Good safety performance. If an arc occurs inside, a structural weakness at the rear of the casing will burst, and the arc exhaust valve on the cabinet will open, directing the overpressure airflow to the outside of the cabinet.
It can be operated manually or electrically, making it easy and reliable to operate.
Three phase integrated installation, good periodicity, few parts, easy to adjust and install, simple and easy to implement, long service life.
Each load switch is sealed and maintenance free for life.

Our Services
12 months warranty
Type test, technical and marketing support.   
Warmly welcome customized design.
After-sales service ..

 
FAQ

1.What is the payment term?
 T/T, wire transfer, west union
2. What kind of VCB do you have?
We have 12kv,24kv,36kv,40.5kv lateral type and withdrawable type vacuum circuit breaker.
3. Warranty period?
Normally 12 months.
 3.How about type test?
Our client passed type test in Europe, and we also type tested in China.

36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6

36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6
36kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm636kv 40kv Electrical Sf6 Gas Disconnector Lbs Load Break Switch Switch Disconnect Sc6 Sm6

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier