Certification: | ISO9001 |
---|---|
Shell Material: | Stainless Steel |
Voltage Level: | Medium Voltage |
Installation: | Fixed |
Structure: | Cabinet |
Current: | AC |
Suppliers with verified business licenses
Description of GSM-12 HV Metal-Enclosured AC Ring Main Unit
Air insulated switchgear GSM-12 HV switchgear metal enclosed AC ring main unit is a new HV apparatus which introduced from abroad and accord with the requirement of rural distribution and city distribution in nation. Main switch, operation mechanism and component use the GSC-12/24 model SF6 switch equipment produced by our company. Also can use the VSG model vacuum circuit breakeraccording to requirement of customer, operation type is manual and motor.
Conditions:
1. Ambient temperature: -25°c~+40°c;
2. Altitude: ≤1000m;
3. Relative humidity: daily average ≤ 95%, monthly average ≤ 90%;
4. Occasions without flammable and explosive matter, without corrosive chemical and frequent severe vibration, without strong shake,
Product feature
Panel structure: The panel body is enclosed by 2mm aluminium-zinc plated steel plate after multi-bending. It is simple, firm, delicate and peculiar.
1. Busbar compartment: The busbar compartment is located in the top and connect with neighhboring panel.
2. Load break switch is a separated unit with SF6 gas.
3. Cable compartment: Approximate 75% room of connecting cable and installing fuse, earthing switch and PT.
4. Mechanism chamber and interlock: The chamber consists of operating mechanism, mechanism interlock, position indicator, auxiliary contact trip coil, charge indicator and interlock.
5. LV chamber: It is lockted in the top. It mainly used for installing instrument, relay and motor.
6. Circuit breaker compartment: The circuit breaker (SF6 or Vacuum) is located below load break switch.
Pressure release:
A. Upper pressure release: It is mainly used for releasing gas pressure which produced by arc accident in busbar load break switch compartment.
B. Down pressure release: It is mainly used for ealeasing gas pressure which produced by arc accident in cable small compartment.
Technical specification of GSM-12 Air Insulated Switchgear
No. |
Item |
Unit |
Technical Data |
1 |
Rated voltage |
KV |
3,6,10 |
2 |
Highest voltage |
KV |
3.6,7.2,12 |
3 |
Main bus-bar rated current |
A |
630 |
4 |
Rated short circuit breaking current |
KA |
50(fuse) |
5 |
Rated short time withstand current |
KA |
20(3S) |
6 |
Rated peak withstand current |
KA |
50 |
7 |
Rated transfer current |
A |
1700 |
8 |
Rated frequency |
HZ |
50/60 |
9 |
Degree of protection |
|
IP3X |
10 |
Bus system |
|
Single bus, single bus with bypass |
11 |
Operating method |
|
Electromagnetism, spring storage energy manual |
Suppliers with verified business licenses