Certification: | CCC, ISO9001 |
---|---|
Shell Material: | Steel Sheet Coated with Aluminum-Zinc Alloy |
Voltage Level: | Medium Voltage |
Installation: | Fixed |
Structure: | Floorstanding |
Current: | AC |
Suppliers with verified business licenses
GRENO's KYN28 series medium voltage switchgear is an air insulated switchgear with a withdrawable vacuum circuit breaker, with a rated voltage of 10-40.5kv. All units can be flexibly combined according to customer requirements to achieve preset functions. This switchgear has stable performance, small size, and flexible maintenance, and is widely used in transmission and distribution systems.
No. |
Description |
Requirement |
1 |
Ambient air temperature |
-10ºC ~ +40ºC |
2 |
Daily average saturated vapor pressure |
≤ 2.2×10mpa |
3 |
Monthly average saturated vapor pressure |
≤ 1.8×10mpa |
4 |
Daily average relative humidity |
≤95% |
5 |
Monthly average relative humidity |
≤90% |
6 |
Altitude |
≤1000m |
7 |
Anti-seismic intensity |
≤ 8° |
7 |
No fire, explosion, danger, severe contamination, chemical corrosion and violent vibration. |
Techincal data1
item |
Unit |
Parameters |
|||
rated voltage |
KV |
7.2 /12 |
|||
rated current |
HZ |
50 |
|||
rated current of circuit breaker |
A |
630\2000 |
|||
rated current of switch cabinet |
A |
630\2000 |
|||
rated current of dynamic stability (4S) |
KA |
16\20\25\31.5\40\50 |
|||
rated current of dynamic stability (peak) |
KA |
40\50\63\80\100\125 |
|||
rated short circuit drop-out current |
KA |
16\20\25\31.5\40\50 |
|||
rated short circuit making current (peak) |
KA |
40\50\63\80\100\125 |
|||
Rated insulation level |
1min power frequency withstand voltage |
KA |
24 |
32 |
42 |
lighting impulse withstand voltage |
KA |
40 |
60 |
75 |
|
protection degree |
IP2X shell: IP4X, it is IP2X when compartment and circuit breaker room is open |
Techincal data2
Serial No. |
Item |
Unit |
Technical parameters |
||||
1 |
Rated voltage |
KV |
24 |
||||
2 |
Rated frequency |
HZ |
50/60 |
||||
3 |
Rated insulation level |
1 min withstand voltage (effective value) |
KV |
Phase to phase & phase to earth |
60 |
Isolation fracture |
79 |
Lighting impulse withstand voltage (peak value) |
125 |
145 |
|||||
Auxiliary control circuit power frequency withstand voltage |
V |
2000 |
|||||
4 |
Rated current |
A |
630,1250,1600,2000,2500,3150 |
||||
5 |
Specified short-circuit dropout current |
KA |
20, 25, 31.5 |
||||
6 |
Rated short-circuit making current (peak value) |
KA |
50, 63, 80 |
||||
7 |
Rated short time withstand current (4S) |
KA |
20, 25, 31.5 |
||||
8 |
Rated peak withstand current |
KA |
50, 63, 80 |
||||
9 |
Auxiliary control circuit rated voltage |
V |
AC or DC 110/220 |
||||
10 |
Protection level |
V |
IP4X (the circuit breaker chamber door is open or isolation chamber is IP2X) |
||||
11 |
Outline dimension |
mm |
1000*1910*24001 |
||||
12 |
Weight |
Kg |
840-1500 |
Suppliers with verified business licenses