Certification: | ISO9001 |
---|---|
Shell Material: | Steel Plate |
Voltage Level: | Medium Voltage |
Installation: | Removable |
Structure: | Cabinet |
Current: | AC |
Suppliers with verified business licenses
Introducing our Medium Voltage Switchgear, an essential Electrical Panel for your power distribution needs. With our ISO9001 certification and sturdy Steel Plate enclosure, you can trust in its reliability. Suitable for Medium Voltage applications.
Product Features
The switchgear is equipped with perfect "Five Prevention" interlock device, which can completely eliminate personnel injury and equipment operation failure caused by human error operation.
· The gas insulated switchgear uses SF6 gas as arc extinguishing and insulating medium
· The switchgear is fully sealed and insulated, and the protection level reaches IP67.
· The switchgear has reliable safe pressure relief channel, which can guarantee the safety of personnel even in extreme cases
· The whole switchgear is not affected by the external environment
Compact size, space-saving, easy installation
· The switchgear can be equipped with electric, remote control and detection devices according to different needs of users.
Technical Satisfaction
Project |
Cable feeder |
Transformer feeder |
Breaker V unit |
Rated voltage |
12/24 |
12/24 |
12/24 |
Rated frequency |
50 or 60 |
50 or 60 |
50 or 60 |
Rated insulation level |
|||
Power frequency withstand voltage |
50/60 |
50/60 |
50/60 |
Lightning impulse withstand voltage |
125/145 |
125/145 |
125/145 |
Rated current |
630 |
≤125 Note1 |
630 |
Breaking closing ability |
|||
Rated active load breaking current |
630 |
|
630 |
Active load breaking current |
31.5 |
|
31.5 |
Rated cable charging breaking current |
10 |
|
10 |
Rated breaking current transfer |
|
2700 |
|
Rated short-circuit breaking current |
|
Note2 |
20 |
Rated short-circuit current |
50 |
|
50 |
Dynamic thermal stability capabilities |
|||
Rated short time withstand current |
20 |
|
20 |
Rated short duration |
3 |
|
3 |
Rated peak withstand current |
50 |
|
50 |
Mechanical life Times |
3000 |
3000 |
3000 |
Other |
|||
Ambient temperature ºC |
-40 ~ +60 |
-40 ~ +60 |
-40 ~ +60 |
Gas pressure...ºC when the gauge... |
0.03 |
0.03 |
0.03 |
Degree of protection |
IP67 Gas tank IP67 |
24kv Technical Parameter | Unit | C module | F module | V module | CB module | ||
Load break switch |
Switch fuse |
Vacuum circuit breaker |
Isolate/ earthing switch |
Vacuum circuit breaker |
Isolate/ earthing switch |
||
Rated Voltage | KV | 24 | 24 | 24 | 24 | 24 | 24 |
Rated Frequency | HZ | 50 | 50 | 50 | 50 | 50 | 50 |
Power Frequence Withstand Voltage | KV | 65 | 65 | 65 | 65 | 65 | 65 |
Impulse Withstand Voltage | KV | 125 | 125 | 125 | 125 | 125 | 125 |
Rated Current | A | 630 | 125 | 630 | |||
Closed Loop | A | 630 | |||||
Off Load Cable Charging | A | 10 | |||||
Rated Active Load Drop-oput Current | A | 31.5 | 630 | ||||
When Earth Fault Frop out Current of Cable Charging | A | 43.3 | |||||
Short Circuit Drop-out Current | KA | 20 | 20 | 25 | |||
Making Capacity | KA | 50 | 50 | 50 | 63 | 63 | |
Rated Short Time Withstand Current | KA/3S | 20 | 16 | 16 | 20 | 20 | |
Transfer Current | A | 1400 | |||||
Loop Resistance | μΩ | ≤300 | ≤600 | ||||
Mechanical Life | Times | 5000 | 5000 | 10000 | 10000 | 10000 | 5000 |
Thank you for considering our products. We are pleased to provide you with the following information:
If you have any further inquiries, please feel free to contact us at any time. We are here to assist you.
Suppliers with verified business licenses